Back
Previous product
Milwaukee MW160 MAX pH/ORP/ISE/Temp Logging Bench Meter Online Sale Original price was: $891.14.Current price is: $356.46.
Next product
Milwaukee MW180 MAX pH/mV/EC/TDS/NaCl/Temp Bench Meter For Sale Original price was: $904.52.Current price is: $361.81.

Milwaukee MW170 MAX EC/TDS/NaCl/Temp Logging Bench Meter Online Sale

Original price was: $755.91.Current price is: $302.36.

Clear
SKU: US-6590075928625 Categories: ,
Description

Description

Milwaukee MW170 MAX EC/TDS/NaCl/Temp Logging Bench Meter

Milwaukee MW170 MAX EC/TDS/NaCl/Temp Logging Bench Meter

The Milwaukee MW170 4-in-1 MAX EC/TDS/NaCl/Temp. Logging Bench Meter is fast, reliable, simple to operate, and is designed with a small lab space footprint.  It is ideal for use by education, horticulture, labs, food processing, water treatment and many other applications with challenging EC/TDS/NaCL/Temp. measurement needs

With easy 1-point EC calibration, 6 standard buffer choices and 2-point temperature calibration, the meter can be quickly calibrated to a higher temperature accuracy compared to other meters.  It also provides a more accurate temperature compensation readings than a 1-point calibration. The MW170 MAX Bench Meter is accurate to ± 1% of reading for EC/TDS and NaCL. 

The meter comes with MA814DB/1 (4 ring) conductivity probe with a built-in temperature sensor allowing the meter to automatically adjust the EC/TDS/NaCl reading for the effect of temperature (ATC).

Features:

  • Fast, easy-to-read results with large duel level digital LCD readout
  • Extreme accuracy to 1% of reading for EC/TDS/NaCl |+/- 0.5°C (+/-0.9°F) 
  • Extended auto-ranging feature for EC/TDS/NaCl
  • Lightweight, sleek design featuring a small benchtop footprint
  • Simple easy-to-use logging; manual log-on-demand or manual log-on-stability up to 1,000 records
  • Micro USB Port download functions
  • GLP data, date and time
  • Easy measurement: just place the probe in the sample, gently stir and wait for the reading to stabilize
  • Single cell factor calibration for EC/TDS/NaCl, automatic simple 1-point calibration and two point for temperature allowing increased accuracy
  • Rugged low maintenance, high performance, easy-to-clean EC/TDS/NaCL/Temp probe.
  • Built in temperature sensor
  • Internal clock date to keep track of different time-dependent functions (calibration, timestamp, calibration time out)
  • 3-foot probe cables for extra flexibility when testing
  • Includes MA9315 electrode holder, cables, adapter and probe

Specifications:

  • EC Range: 0.00 to 29.99 uS/cm / 30.0 to 299.9 uS/cm
  • EC Range: 300 to 2999 uS/cm
  • EC Range: 3.00 to 29.99 mS/cm / 30.0 to 200.0 mS/cm
  • EC Range: up to 500 mS/cm absolute conductivity**
  • TDS Range: 0.00 to 14.99 ppm (mg/L)
  • TDS Range: 15.0 to 149.9 ppm (mg/L) / 150 to 1499 ppm (mg/L)
  • TDS Range: 1.50 to 14.99 g/L / 15.0 to 100.0 g/l
  • TDS Range: up to 250.0 g/L absolute TDS**
  • TDS Range: up to 400 g/L absolute TDS** (with 0.80 factor)
  • Salinity Range: 0.0 to 400.0% NaCl / 2.00 to 42.00 PSU
  • Salinity Range: 0.00 to 80.00 g/L
  • Range: -20.0 to 120.00°C (-4.0 to 248.0°F)
  • EC Resolution: 0.01 uS/cm / 0.1 uS/cm / 1 uS/cm
  • EC Resolution: 0.01 mS/cm / 0.1 mS/cm
  • TDS Resolution: 0.01 ppm / 0.1 ppm / 1 ppm
  • TDS Resolution: 0.01 g/L / 0.1 g/L
  • Salinity Resolution: 0.1% NaCl / 0.01 PSU / 0.01 g/L
  • Temperature Resolution: 0.1°C / 0.1°F)
  • Accuracy @ 25°C / 77°F
  • EC: ± 1% of reading / ±0.05 uS/cm or 1 digit, whichever is greater
  • TDS: ±1% of reading / ±0.03 ppm or 1 digit, whichever is greater
  • Salinity: ±1% of reading
  • Temperature: ±0.5°C (±0.9°F)
  • Calibration
  • EC/TDS: single cell factor calibration, 6 standards: 84 uS/cm, 1413 uS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm / 1-point offset: 0.00 uS/cm
  • Salinity: one point with MA9066 salinity calibration solution
  • Temperature Compensation: Automatic or manual from -20 to 120°C (-4.0 to 248.0°F) or NO TC without temperature compensation
  • Conductivity temperature coefficient: 0.00 to 6.00 % / °C (EC and TDS only) | Default value: 1.90 % / °C
  • TDS factor: 0.40 to 0.80 / Default value: 0.50
  • EC Probe: MA814DB/1 4 ring
  • Temperature probe: Built-in temperature sensor
  • Logging: Maximum 1,000 log records (stored in up to 100 lots) / on demand, 200 logs on stability, 200 logs, interval logging 1000
  • PC Connectivity: 1 micro USB port
  • Power Supply: 12 VDC adapter (included)
  • Battery Type: Internal
  • Battery life: Approx. 8 hours of use
  • Environment: 0 to 50°C / 32 to 122°F; max RH 95%
  • Dimensions: 230 x 160 x 95 mm (9.0 x 6.3 x 3.7 inches)
  • Weight: 0.9 kg / 2.00 lbs.
  • Warranty: 3 years meter

** Absolute conductivity (or TDS) is the conductivity value without temperature compensation

Milwaukee MW170 Manual

CARE AND USE

EC meters usually start performing poorly because of problems with the sediment on the conductivity probe’s rings. The dirty rings on the probe can change impedance. Cleaning the rings is simple.  Slide the plastic shield off and clean with DI water and soft cloth to keep your readings accurate.

The life of your meter can also be extended in the following ways:

Storage – When not in use, store the meter and probe in a safe area to avoid damage. The EC probe is stored dry. 

Calibration – The MW170 MAX is easy 1-point EC/TDS/NaCl calibration for ease-of-use and 2-point temperature calibration for best accuracy in (ATC).  Calibrating regularly is best to keep your PRO MW170 4-in-1 MAX Bench meter accurate for all your readings.

Additional information

Additional information

Title

Default Title, Default Title (Wholesale)

Shipping & Delivery

We accept returns on non-sale items that are in original packaging, unused, and unwashed within 30 days of receipt. Please follow our returns/exchanges process below. If items do not meet our requirements for return, they will be shipped back to you in lieu of a refund. Shipping and handling charges are non-refundable (exceptions may apply).

Returns & Exchanges Process: If item(s) fit within our returns guidelines found in the Returns. Please allow 7-10 business days for the credit to appear on your account after your return is processed.